DESCRIPTION
Refer to the system description for DTC P2757 (See page
).
DTC No. |
DTC Detection Condition |
Trouble Area |
---|---|---|
P2759 |
Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1 trip detection logic). |
|
MONITOR DESCRIPTION
When an open or short in a shift solenoid valve SLU circuit is detected, the ECM determines there is a malfunction. The ECM will illuminate the MIL and store this DTC.
MONITOR STRATEGY
Related DTCs |
P2759: Shift solenoid valve SLU/Range check |
Required sensors/Components |
Shift solenoid valve SLU |
Frequency of operation |
Continuous |
Duration |
1 sec. |
MIL operation |
Immediately |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
All:
The monitor will run whenever the following DTCs are not stored |
None |
Ignition switch |
ON |
Starter |
OFF |
Battery voltage |
12 V or higher |
Battery voltage |
10 V or higher, and below 12 V |
Target current |
Below 0.75 A |
Battery voltage |
8 V or higher |
Target current |
0.25 A or higher |
TYPICAL MALFUNCTION THRESHOLDS
One of the following conditions is met: Condition (A), (B) or (C)
Condition (A) and (B):
Output duty cycle |
100% or more |
Output duty cycle |
0% or less |
COMPONENT OPERATING RANGE
Output duty cycle |
More than 3%, and less than 100% |
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
PROCEDURE
1. |
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU) |
(a) Disconnect the E1 transmission wire connector. |
|
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection |
Condition |
Specified Condition |
---|---|---|
21 (SLU+) - 22 (SLU-) |
20°C (68°F) |
5.0 to 5.6 Ω |
21 (SLU+) - Body ground |
Always |
10 kΩ or higher |
22 (SLU-) - Body ground |
Always |
10 kΩ or higher |
*a |
Component without harness connected (Transmission Wire) |
NG | ![]() |
GO TO STEP 3 |
|
2. |
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
(a) Disconnect the ECM connector. |
|
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection |
Condition |
Specified Condition |
---|---|---|
E19-2 (SLU+) - E19-1 (SLU-) |
20°C (68°F) |
5.0 to 5.6 Ω |
E19-2 (SLU+) - Body ground |
Always |
10 kΩ or higher |
E19-1 (SLU-) - Body ground |
Always |
10 kΩ or higher |
*a |
Rear view of wire harness connector (to ECM) |
OK | ![]() |
REPLACE ECM |
NG | ![]() |
REPAIR OR REPLACE HARNESS OR CONNECTOR |
3. |
INSPECT SHIFT SOLENOID VALVE SLU |
(a) Remove shift solenoid valve SLU (See page
|
|
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection |
Condition |
Specified Condition |
---|---|---|
1 - 2 |
20°C (68°F) |
5.0 to 5.6 Ω |
(c) Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
OK:
Measurement Condition |
Specified Condition |
---|---|
|
Valve moves and makes an operating noise |
*1 |
Shift Solenoid Valve SLU |
OK | ![]() |
REPLACE TRANSMISSION WIRE |
NG | ![]() |
REPLACE SHIFT SOLENOID VALVE SLU |
Disassembly
DISASSEMBLY
PROCEDURE
1. REMOVE ROOM LIGHT BRACKET
(a) Disengage the guide to remove the room light bracket.
2. REMOVE SLIDING ROOF DRIVE GEAR SUB-ASSEMBLY
(a) Remove the 2 bolts and sliding roof drive gear sub-assembly.
...
Removal
REMOVAL
PROCEDURE
1. REMOVE FRONT DOOR SCUFF PLATE LH (for Double Cab)
Click here
2. REMOVE FRONT DOOR SCUFF PLATE LH (for Access Cab)
Click here
3. REMOVE COWL SIDE TRIM BOARD LH
Click here
4. REMOVE INSTRUMENT CLUSTER CENTER FINISH PANEL SUB-ASSEMBLY
Click here
5. REMOVE INSTRUME ...
Fail-safe Chart
FAIL-SAFE CHART
HINT:
If any of the following auto cancel conditions are detected while the dynamic
radar cruise control system is controlling vehicle speed, the system clears the
stored vehicle speed and cancels control of vehicle speed by the dynamic radar cruise
control system.
Automatic ...