DATA LIST / ACTIVE TEST
1. DATA LIST
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Check the value(s) by referring to the table below.
Air Conditioner|
Tester Display |
Measurement Item/Range |
Normal Condition |
Diagnostic Note |
|---|---|---|---|
|
Room Temperature Sensor |
Cooler thermistor (room temperature sensor) / Min.: -6.50°C (20.30°F) Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed |
- |
|
Ambient Temp Sensor |
Ambient temperature sensor / Min.: -23.30°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed |
- |
|
Adjusted Ambient Temp |
Adjusted ambient temperature / Min.: -30.80°C (-23.44°F) Max.: 50.80°C (123.44°F) |
- |
- |
|
Evaporator Fin Thermistor |
Cooler thermistor sensor (evaporator temperature sensor) / Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed |
- |
|
Evaporator Target Temp |
Evaporator target temperature / Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed |
- |
|
Engine Coolant Temp |
Engine coolant temperature sensor / Min.: 1.30°C (34.34°F) Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature displayed |
- |
|
Blower Motor Speed Level |
Blower motor speed level / Min.: 0 Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases |
- |
|
Regulator Pressure Sensor |
Air conditioner pressure sensor / Min.: -66.22 psi (gauge) Max.: 477.68 psi (gauge) |
Actual pressure is displayed |
- |
|
Electric Heater Count*1 |
Maximum heater operation level / Min.: 0 Max.: 3 |
Maximum possible operation level of quick heater assembly (PTC heater) displayed |
- |
|
Electric Heater Active Level*1 |
Actual heater operation level / Min.: 0 Max.: 3 |
Actual operation level of quick heater assembly (PTC heater) displayed |
- |
|
Shift Set Temperature |
Shift set temperature / 2C decr, 1C decr, Normal, 1C incr, 2C incr |
Customized value displayed |
- |
|
Air Inlet Mode*2 |
Air inlet mode / Auto or Manual |
Customized value displayed |
- |
|
Compressor Mode |
Compressor mode / Auto or Manual |
Customized value displayed |
- |
|
Fan speed increment control |
Fan speed increment control / Slow, Normal, Fast |
Customized value displayed |
- |
|
Foot/DEF Auto Mode |
Foot/DEF auto mode / ON or OFF |
Customized value displayed |
- |
|
Foot/DEF Auto Blow Up |
Foot/DEF auto blower speed increase / ON or OFF |
Customized value displayed |
- |
|
Refrigerant Gas Type |
Refrigerant gas type / R134a or 1234yf |
Refrigerant gas type displayed |
- |
|
Set Temperature (D Side) |
Driver side set temperature / Min.: MAX COLD Max.: MAX HOT |
Driver side set temperature displayed |
- |
|
Set Temperature (P Side) |
Front passenger side set temperature / Min.: MAX COLD Max.: MAX HOT |
Front passenger side set temperature displayed |
- |
|
Outside Air Mode Auto Switch Function |
Outside air mode auto switch function / ON or OFF |
Customized value displayed |
- |
|
Air Mix Damper Position (Driver Side) |
Air mix damper servo motor (for driver side) actual position / Min.: -14.0% Max.: 113.5% |
MAX COOL: 0.0% MAX HOT: 100.0% |
- |
|
Air Mix Damper Position (Passenger Side) |
Air mix damper servo motor (for front passenger side) actual position / Min.: -14.0% Max.: 113.5% |
MAX COOL: 0.0% MAX HOT: 100.0% |
- |
|
Air Outlet Damper Position |
Mode damper servo motor actual position / Min.: -14.0% Max.: 113.5% |
FACE: 0.0% DEF: 100.0% |
- |
|
Air Inlet Damper Position |
Air inlet damper servo motor actual position / Min.: -14.0% Max.: 113.5% |
FRESH: 0.0% RECIRCULATION: 100.0% |
- |
|
Air Mix Damper Target (Driver Side) |
Air mix damper servo motor (for driver side) target position / Min.: -14.0% Max.: 113.5% |
MAX COOL: 0.0% MAX HOT: 100.0% |
- |
|
Air Mix Damper Target (Passenger Side) |
Air mix damper servo motor (for front passenger side) target position / Min.: -14.0% Max.: 113.5% |
MAX COOL: 0.0% MAX HOT: 100.0% |
- |
|
Air Outlet Damper Target |
Mode damper servo motor target position / Min.: -14.0% Max.: 113.5% |
FACE: 0.0% DEF: 100.0% |
- |
|
Air Inlet Damper Target |
Air inlet damper servo motor target position / Min.: -14.0% Max.: 113.5% |
FRESH: 0.0% RECIRCULATION: 100.0% |
- |
|
DEF (PSW/Lock) Mode Setting |
DEF (PSW/Lock) Mode Setting / Link or Normal |
Customized value displayed |
- |
|
Number of Trouble Codes |
Number of trouble codes / Min.: 0 Max.: 255 |
Number of DTCs displayed |
- |
2. ACTIVE TEST
Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Active Test.
(e) Check the operation by referring to the table below.
Air Conditioner|
Tester Display |
Test Part |
Control Range |
Diagnostic Note |
|---|---|---|---|
|
Blower Motor |
Blower motor with fan sub-assembly |
Min.: 0, Max.: 31 |
- |
|
Air Mix Damper (Driver Side) |
Air mix damper servo motor (for driver side) |
Min.: -14.0% , Max.: 113.5% |
Operates between 0 and 100% |
|
Air Mix Damper (Passenger Side) |
Air mix damper servo motor (for front passenger side) |
Min.: -14.0% , Max.: 113.5% |
Operates between 0 and 100% |
|
Air Outlet Damper (Driver Side) |
Mode damper servo motor |
Min.: -14.0% , Max.: 113.5% |
Operates between 0 and 100% |
|
Air Inlet Damper (Rear) |
Air inlet damper servo motor |
Min.: -14.0% , Max.: 113.5% |
Operates between 0 and 100% |
|
Magnetic Clutch Relay |
Air conditioning system operation |
OFF, ON |
- |
|
Mirror Heater Relay |
Mirror heater |
OFF, ON |
- |
|
Electrical Fan |
Electrical Fan |
OFF, ON |
- |
|
Heater Active Level*1 |
Quick heater assembly |
Min.: 0, Max.: 3 |
- |
Terminals Of Ecu
Diagnostic Trouble Code ChartAir Outlet Damper Control Servo Motor Circuit (B1443/43)
DESCRIPTION
This No. 1 air conditioning radiator damper servo sub-assembly (for mode switching)
is controlled by the air conditioning amplifier assembly and moves the mode damper
to the desired position.
DTC No.
DTC Detection Condition
Trouble Area
...
Installation
INSTALLATION
PROCEDURE
1. INSTALL FRONT AXLE HUB
2. INSTALL FRONT SUSPENSION UPPER ARM
(a) Install a new nut and clip.
Torque:
110 N·m {1122 kgf·cm, 81 ft·lbf}
3. INSTALL FRONT SUSPENSION LOWER ARM
(a) Install the front suspension lower arm with the 2 bolts.
Torque:
160 N·m {1631 ...
Voice is not Recognized
PROCEDURE
1.
CHECK CONDITION
(a) Check if the system voice recognition level is low for a particular voice.
Result
Result
Proceed to
System voice recognition level is low for any voice.
A
System vo ...