Installation
ComponentsData List / Active Test
DATA LIST / ACTIVE TEST
HINT:
By accessing the Data List displayed on the Techstream, you can perform such
functions as reading the values of switches and sensors without removing any parts.
Reading the Data List is the first step of troubleshooting and is one method to
shorten labor time.
...
Neutral Position Switch Circuit
DESCRIPTION
The ECM uses the neutral position switch installed to the manual transmission
assembly to detect when the transmission is in the neutral position.
WIRING DIAGRAM
PROCEDURE
1.
READ VALUE USING TECHSTREAM (NEUTRAL SWITCH)
(a) Connect the Techstream ...
Fail-safe Chart
FAIL-SAFE CHART
1. Fail-safe
This function minimizes the loss of operation when any abnormality occurs in
a sensor or solenoid.
Fail-safe Control List
Malfunction Part
Function
Transmission revolution sensor (NT)
During a transmission revolutio ...