Toyota Tacoma manuals

Toyota Tacoma (2015-2018) Service Manual: Air Mix Control Servo Motor

Inspection

INSPECTION

PROCEDURE

1. INSPECT AIR MIX CONTROL SERVO MOTOR (for Manual Air Conditioning System)

(a) Inspect the servo motor operation.

Text in Illustration

*a

0 V

*b

6V

*c

12 V

*d

Notches

(1) When 12 V is applied between terminals 4 (IGN) and 1 (GND), and 0 V is applied between terminals 2 (SIG) and 1 (GND), check that the line connecting the 2 notches moves to the 0 V position.

If the result is not as specified, replace the air mix control servo motor.

(2) When 12 V is applied between terminals 4 (IGN) and 1 (GND), and 6 V is applied between terminals 2 (SIG) and 1 (GND), check that the line connecting the 2 notches moves to the 6 V position.

If the result is not as specified, replace the air mix control servo motor.

(3) When 12 V is applied between terminals 4 (IGN) and 1 (GND), and between terminals 2 (SIG) and 1 (GND), check that the line connecting the 2 notches moves to the 12 V position.

If the result is not as specified, replace the air mix control servo motor.

2. INSPECT AIR MIX CONTROL SERVO MOTOR (for Automatic Air Conditioning System)

(a) Inspect the servo motor operation.

(1) Connect the positive (+) lead from the battery to terminal 7 (MHD) and negative (-) lead to terminals 1 (SG), then check that the shaft rotates clockwise smoothly.

(2) Connect the positive (+) lead from the battery to terminal 6 (MCD) and negative (-) lead to terminal 1 (SG) then check that the shaft rotates counterclockwise smoothly.

If the operations are not as specified, replace the air mix control servo motor.

Air Inlet Control Servo Motor
Inspection INSPECTION PROCEDURE 1. INSPECT AIR INLET CONTROL SERVO MOTOR (a) Inspect the servo motor operation. (1) Connect the positive (+) lead from the battery to terminal 1 (FR ...

Air Outlet Control Servo Motor
Inspection INSPECTION PROCEDURE 1. INSPECT MODE CONTROL SERVO MOTOR (a) Inspect the servo motor operation. (1) When 12V is applied between terminals 4 (IGN) and 1 (GND), and 0V ...

Other materials:

Adjusting the position of the air outlets
Center outlets Direct air flow to the left or right, up or down. Right and left side outlets Direct air flow to the left or right, up or down. Opening and closing the air outlets Center outlets   Open the vent. Close the vent. Right and left side outlets Open the vent. ...

Registration
REGISTRATION CAUTION / NOTICE / HINT HINT: Register a new recognition code when replacing the door control transmitter module set sub-assembly or the door control receiver. Add mode is used to retain the already registered codes while registering a new recognition code. This m ...

Customize Parameters
CUSTOMIZE PARAMETERS PROCEDURE 1. CUSTOMIZE INTUITIVE PARKING ASSIST SYSTEM (a) Customizing with the Techstream NOTICE: When the customer requests a change in a function, first make sure that the function can be customized. Be sure to make a note of the current settings before c ...