ON-VEHICLE INSPECTION
PROCEDURE
1. INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET
(a) This is a method to specify trouble areas by using a manifold gauge set. Read the manifold gauge pressure when the following conditions are established.
Test conditions:
- Engine has been warmed up.
- All doors are fully open.
- A/C switch is ON.
- Engine is running at 1,500 rpm.
- Air inlet mode selector damper is set at recirculation.
- Temperature control switch is in MAX. COLD position.
- Blower speed control switch is in HI position.
- Air temperature at the air inlet is 30 to 35°C (86 to 95°F).
Gauge readings (Reference)
|
(1) When the refrigerant volume is proper: Gauge reading: Low pressure side: 150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi) High pressure side: 1370 to 1570 kPa (14.0 to 16.0 kgf/cm2, 199 to 228 psi) |
|
(2) When there is moisture in the refrigeration system:
|
Symptoms |
Probable Cause |
Diagnosis |
Corrective Actions |
|---|---|---|---|
|
During operation, pressure on low pressure side cycles between normal and vacuum |
Moisture in refrigeration system freezes at expansion valve orifice, causing temporary stop of cycle. However, when melted, normal state restored |
|
|
(3) When cooling is insufficient:
|
Symptoms |
Probable Cause |
Diagnosis |
Corrective Actions |
|---|---|---|---|
|
Gas leakage from refrigeration system |
|
|
(4) When the circulation of the refrigerant is poor:
|
Symptoms |
Probable Cause |
Diagnosis |
Corrective Action |
|---|---|---|---|
|
Refrigerant flow obstructed by dirt in condenser |
Condenser clogged |
Replace condenser |
(5) When the refrigerant does not circulate:
|
Symptoms |
Probable Causes |
Diagnosis |
Corrective Actions |
|---|---|---|---|
|
|
Refrigerant does not circulate |
|
(6) When the refrigerant is overcharged or cooling of condenser is insufficient:
|
Symptoms |
Probable Causes |
Diagnosis |
Corrective Actions |
|---|---|---|---|
|
Pressure extremely high on both low and high pressure sides |
|
|
|
(7) When there is air in the refrigeration system:
|
Symptoms |
Probable Cause |
Diagnosis |
Corrective Actions |
|---|---|---|---|
|
Air in refrigeration system |
|
|
(8) When the expansion valve malfunctions:
|
Symptoms |
Probable Cause |
Diagnosis |
Corrective Action |
|---|---|---|---|
|
Trouble in expansion valve |
|
Replace expansion valve |
(9) When the compressor is defective:
|
Symptoms |
Probable Cause |
Diagnosis |
Corrective Action |
|---|---|---|---|
|
Internal leakage in compressor |
|
Repair or replace compressor |