Inspection
INSPECTION
PROCEDURE
1. INSPECT BLOWER MOTOR
|
(a) Inspect the blower motor.
(1) Connect the positive (+) lead from to terminal 1 and negative (-)
lead to terminal 2, then check that the motor operates smoothly.
CAUTION:
- Use safety glasses
- Do not use battery power, use DC power supply (30 A).
- Do not operate the motor and fan assembly at over 5 V.
- Be sure to hold the motor in a stable and safe way.
If the result is not as specified, replace the blower motor.
|
|
INSTALLATION
PROCEDURE
1. INSTALL COOLER CONDENSER ASSEMBLY
(a) Engage the 2 claws to install the 2 condenser upper brackets.
(b) Engage the 2 claws to install the 2 condenser lower brackets.
...
Inspection
INSPECTION
PROCEDURE
1. INSPECT BLOWER RESISTOR
(a) Check the resistance.
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance ...