Ignition Coil And Spark Plug
Parts LocationStarter Relay Circuit Short to Battery (P061512)
DESCRIPTION
While the engine is being cranked, positive battery voltage is applied to terminal
STA of the ECM. If the ECM detects the starter control (STA) signal while the vehicle
is being driven, it determines that there is a malfunction in the STA circuit. The
ECM then illuminates the MIL ...
Fail-safe Chart
FAIL-SAFE CHART
FAIL-SAFE FUNCTION
(a) When a malfunction occurs in the lane departure alert system, a message will
be displayed on the multi-information display in the combination meter assembly
and the lane departure alert system will be disabled depending on the malfunction.
War ...
TS and CG Terminal Circuit
DESCRIPTION
In Test Mode (signal check), a malfunction in the speed sensor that cannot be
detected when the vehicle is stopped can be detected while driving.
Sensor check mode can be entered by connecting terminals TS and CG of the DLC3
and turning the ignition switch from off to ON.
WIRING D ...