Inspection
INSPECTION
PROCEDURE
1. INSPECT AIR MIX CONTROL SERVO MOTOR (for Manual Air Conditioning System)
|
(a) Inspect the servo motor operation. Text in Illustration
(1) When 12 V is applied between terminals 4 (IGN) and 1 (GND), and 0 V is applied between terminals 2 (SIG) and 1 (GND), check that the line connecting the 2 notches moves to the 0 V position. If the result is not as specified, replace the air mix control servo motor. (2) When 12 V is applied between terminals 4 (IGN) and 1 (GND), and 6 V is applied between terminals 2 (SIG) and 1 (GND), check that the line connecting the 2 notches moves to the 6 V position. If the result is not as specified, replace the air mix control servo motor. (3) When 12 V is applied between terminals 4 (IGN) and 1 (GND), and between terminals 2 (SIG) and 1 (GND), check that the line connecting the 2 notches moves to the 12 V position. If the result is not as specified, replace the air mix control servo motor. |
|
2. INSPECT AIR MIX CONTROL SERVO MOTOR (for Automatic Air Conditioning System)
|
(a) Inspect the servo motor operation. (1) Connect the positive (+) lead from the battery to terminal 7 (MHD) and negative (-) lead to terminals 1 (SG), then check that the shaft rotates clockwise smoothly. (2) Connect the positive (+) lead from the battery to terminal 6 (MCD) and negative (-) lead to terminal 1 (SG) then check that the shaft rotates counterclockwise smoothly. If the operations are not as specified, replace the air mix control servo motor. |
|