PRECAUTION
1. Check that the battery cables are connected to the correct terminals.
2. Disconnect the battery cables when the battery is given a quick charge.
3. Do not perform tests with a high voltage insulation resistance tester.
4. Never disconnect the battery while the engine is running.
5. Check that the charging cable nut is tightened on terminal B of the generator and the engine room relay block.
6. IGNITION SWITCH EXPRESSIONS
HINT:
The type of ignition switch used on this model differs depending on the specifications of the vehicle. The expressions listed in the table below are used in this section.
Expression |
Ignition Switch (Position) |
Engine Switch (Condition) |
---|---|---|
Ignition Switch off |
Lock |
Off |
Ignition Switch ACC |
ACC |
On (ACC) |
Ignition Switch ON |
ON |
On (IG) |
Engine Start |
START |
Start |
Precaution
PRECAUTION
PRECAUTION FOR DISCONNECTING CABLE FROM NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable from the negative (-) battery terminal,
initialize the following systems after the cable is reconnected.
Click here
If the battery has been discharged and char ...
Open or Short in Master Cylinder Pressure Sensor (C1421,C1423,C1424,C142A,C1449)
DESCRIPTION
DTC No.
Detection Item
DTC Detection Condition
Trouble Area
C1421
Open or Short in Master Cylinder Pressure Sensor
Any of the following is detected:
When voltage at terminal +BS is 9.5 V or ...
Clutch Switch
Components
COMPONENTS
ILLUSTRATION
Removal
REMOVAL
PROCEDURE
1. PRECAUTION
NOTICE:
After turning the engine switch off, waiting time may be required before disconnecting
the cable from the battery terminal. Therefore, make sure to read the disconnecting
the cable from the battery t ...